EPC Products Teaching and Research Laboratory Equipment Heat Transfer HT16X – Radiation Errors in Temperature Measurement
產品中心
BBS|Hot Topic
HT16X – Radiation Errors in Temperature Measurement

Model:HT16X

Use:The velocity of the air can be changed by adjusting a throttle plate at the fan inlet and measured by an anemometer in the fan outlet duct.

Standard:

Related Products

Description


Radiative heat transfer between a thermometer and its surroundings may significantly affect temperature readings obtained from the thermometer, especially when the temperature of a gas is to be measured while the thermometer ‘sees’ surrounding surfaces at a higher or lower temperature than the gas.

The error in the reading from the thermometer is also affected by other factors such as the gas velocity over the thermometer, the physical size of the thermometer and the emissivity of the thermometer body. In this equipment a group of thermocouples are used to measure the temperature of a stream of air, at ambient temperature, passing through the centre of a duct while the wall of the duct is elevated in temperature to subject the thermocouples to a source of thermal radiation.

Each thermocouple gains heat by radiation from the heated wall and loses heat by convection to the air stream and conduction along the wire. The net result is an increase in the temperature of the thermocouple above the temperature of the air stream it is supposed to measure. The result is an error in the reading from the thermocouple. A radiation shield can be positioned in the duct to show the effect of screening the thermocouples from thermal radiation from the duct wall.

The effect of air velocity past the test thermocouples can be demonstrated by adjusting the air flow. This is achieved by a variable speed fan controlled using the software, by adjusting the power supplied or using a PID controller to automatically achieve air velocity set-point.

A vane-type anemometer within the fan outlet duct enables the air velocity through the heated section to be measured.

A radiation shield, which remains close to the air temperature, can be raised or lowered over the thermocouples to demonstrate the change in readings when a radiation shield is used. This radiation shield is controlled by an electro-mechanical servo actuator under software control.



Experimental Capabilities


  • Errors associated with radiative heat transfer:

– Effect of wall temperature on measurement error

– Effect of air velocity on measurement error

– Effect of thermocouple style on measurement error

  • Methods for reducing errors due to radiation:

– Design of a radiation-resistant thermometer

– Use of a radiation shield to surround the thermometer